HI-96715C Ammonia Portable Photometer Kit, Medium Range Product Code: VM715

Information

Designed to measure the ammonia-nitrogen content in water samples, the HI-96715C is ideal for use in a wide range of applications.

Offering high levels of accuracy as well as being water resistant, portable and easy to use, this meter is hugely popular with operators across the water industry.

A measurement range of 0.00 to 9.99 ppm makes it the optimum solution for quick, efficient and economical ammonia measurement.

Ideal for

Water: fresh and salt water fish tanks and farms, lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water

Key features

Clear display messages make the instrument quick and easy to operate.

The powerful Cal Check calibration function means that there is no need to return the instrument to the laboratory to check its efficiency. Samples can be checked and validation confirmed at the press of a button.

Positive locking system ensures the cuvette is located in the same position each and every time is it placed in the measurement cell.

Auto shut off feature turns meter off after 10 minutes of non-use to save battery life.

Fully water resistant

Clear easy to use function buttons

Direct readout of parameter measured

Calibration check solution available - HI 96715-11

Designed for precision

With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NIST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.

All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.

Supplied with

2 glass cuvettes

9V battery

Attaché case

CAL CHECK Standards

Cuvette cleaning cloths

Please Note: reagents can be ordered separately

 

Specifications

Parameter

 

Ammonia, Medium Range

Range

 

0.00 to 9.99 mg/L (as NH³-N)

Accuracy

 

±0.12 mg/L @ 6.00 mg/L

Filter

 

Narrow band @ 466 nm

Method

 

Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.

Light Source

 

Tungsten lamp; LED

Environment

 

0 to 50°C (32 to 122°F); Max 95% RH non-condensing

Battery Type / Life

 

(1) 9V/approx. 200 hours continuous use

Auto Shut-off

 

After 10 min. of non-use in measurement mode

Dimensions

 

192 x 102 x 67 mm (7.6 x 4 x 2.6")

Weight

 

290 g (10 oz.)